Minimum Living Standards:
6 Technical Requirements
This article summarises the specific certification standards from a landlord's perspective. Each standard includes a "common non-compliance scenario" to help landlords anticipate what works their unit may require.
Minimum Internal Floor Area of 8 sq m
The "internal floor area" (including toilet) of each subdivided unit must not be less than 8 sq m.
Minimum Clear Ceiling Height of 2.3 m
The lowest point of the ceiling in a subdivided unit must not be below 2.3 m.
Mechanical Ventilation
Each subdivided unit must be equipped with a mechanical ventilation system achieving a minimum of 5 air changes per hour (ACH).
Separate Toilet
Each subdivided unit must have a separate toilet (including WC, washbasin, and shower facility) — shared toilets are not permitted.
Independent Water and Electricity Metering
Each subdivided unit must have independent water and electricity meters enabling separate measurement of consumption.
Fire Compartmentation and Smoke Protection
The entrance to each subdivided unit must be fitted with a one-hour fire- and smoke-resisting door, and be equipped with a smoke detector and fire extinguisher.
Next reading: Key Timeline — understand the critical dates for registration, certification, and enforcement.