Basic Housing Unit (BHU) Minimum Living Standards:
6 Technical Requirements
This article summarises the specific certification standards from a landlord's perspective. Each standard includes a "common non-compliance scenario" to help landlords anticipate what works their unit may require.
Minimum Internal Floor Area of 8 sq m
The "internal floor area" (including toilet) of each subdivided unit must not be less than 8 sq m.
Minimum Clear Ceiling Height of 2.3 m
The lowest point of the ceiling in a subdivided unit must not be below 2.3 m; where a beam is present, the clear height below the beam must not be below 2.0 m.
Lighting and Ventilation (Option A or B)
Each subdivided unit (and its toilet) must meet lighting and ventilation requirements under either of two options:
Option A (natural ventilation): complies with sections 30, 31, 32 and 33 (for rooms) or section 36 (for the toilet) of the Building (Planning) Regulations.
Option B (mechanical ventilation): rooms must have at least one openable window with a glazed area of at least 0.1 sq m, artificial lighting, and mechanical ventilation achieving at least 5 air changes per hour (5 ACH); the toilet must have artificial lighting and mechanical ventilation achieving at least 5 ACH (no window is mandated).
Self-Contained Toilet
Each subdivided unit must have an enclosed, waterproofed toilet for the exclusive use of its occupant — shared toilets are not permitted. The Ordinance explicitly requires all three of the following fixtures inside the toilet: a flush toilet, a washbasin, and a bathtub or shower (all three are mandatory; none may be omitted). In addition, a water point and sink must be provided outside the toilet, with the surrounding area waterproofed.
Independent Water and Electricity Metering
Each subdivided unit must have a water meter provided specifically for that unit by the Water Supplies Department, and an electricity meter provided specifically for that unit by CLP or HK Electric, enabling separate measurement of consumption. (Gas sub-metering is not mandated by the Ordinance; landlords with gas-supplied units should confirm requirements separately with their gas utility company.)
Fire Compartmentation and Smoke Protection
A subdivided unit's design, construction, and partitioning must, in the event of a fire: prevent fire from spreading within and outside the flat; have sufficient fire and smoke resistance; provide sufficient escape routes; and maintain structural stability. In practice, this means the door between each subdivided unit and the common corridor must meet FD30 (30-minute fire resistance), partition walls between units must meet FRR-60 (60-minute fire resistance), each unit and the common parts of the principal flat must each have sufficient independent smoke detectors, and the common parts must also have sufficient fire extinguishers — both inspected at least once every 12 months.
Next reading: Floor Area and Ceiling Height: How They're Measured — how the 8 sq m threshold is measured and whether the toilet counts. | BHU Compliance Renovation Cost Estimates — detailed cost ranges and case estimates for each renovation item. | Key Timeline — understand the critical dates for registration, certification, and enforcement.